Burnerlogix YB110UV 

Microprocesser based BMS for the industrial boiler, burner and process industry.

Description

The Fireye® BurnerLogixTM System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. In conjunction with limit and operating controls, it programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. Through SMART LED’S, the control provides current operating status and lockout information in the event of a safety shutdown. Optional VFD and LCD displays are available that may be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information. MODBUS output for current state, inputs and outputs active and lockout history.

  • 110 or 230v operation
  • For use with Gas and Oil or duel fuel burners
  • Can be used with UV, UV self check, Ionisation rod, infrared or any flame scanner that provides a relay output.
  • Complete programmmable control for burner sequencing
  • Small footprint
  • Choice of wiring bases
  • LED and VFD display
  • Burner lockout history
  • Modbus comms
  • Valve proof of closure
  • Compatible with YZ300 first out annuciator

Y MODULE CHASSIS (INCLUDES AMPLIFIER)

 

 

YB110UV

Chassis, 120 VAC, 50/60 Hz with UV non self-check amplifier. UL, FM, CE Approved.

BL-1001

YB110UVSC

Chassis, 120 VAC, 50/60 Hz with UV self-check amplifier. UL, FM, CE Approved.

BL-1001

YB110IR

Chassis, 120 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, FM, CE Approved.

BL-1001

YB110IR2

Chassis, 120 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, FM, CE Approved. Special application only, consult factory.

BL-1001

YB110FR

Chassis, 120 VAC, 50/60 Hz with flame rectification amplifier. UL, FM, CE Approved. 

BL-1001

YB110DC

Chassis, 120 VAC, 50/60 Hz with direct coupled amplifier for use with Phoenix and Insight scanners.  UL, FM, CE Approved. 

BL-1001

YB230UV

Chassis, 230 VAC, 50/60 Hz with UV non self-check amplifier. FM, CE Approved.

BL-1001

YB230UVSC

Chassis, 230 VAC, 50/60 Hz with UV self-check amplifier, FM, CE Approved.

BL-1001

YB230IR

Chassis, 230 VAC, 50/60 Hz with IR Auto-Check amplifier. FM, CE Approved.

BL-1001

YB230IR2

Chassis, 230 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, FM, CE Approved. Special application only, consult factory.

BL-1001

YB230FR

Chassis, 230 VAC, 50/60 Hz with flame rectification amplifier. FM, CE Approved. 

BL-1001

YB230DC

Chassis, 230 VAC, 50/60 Hz with direct coupled amplifier for use with Phoenix and Insight scanners. FM, CE Approved. 

BL-1001

KEYPAD / DISPLAY MODULE (OPTIONAL)

 

 

BLV512

Keypad/Display, 2 line X 16 characters, VACUUM FLUORESCENT DISPLAY (VFD), with cable. Operates -40F  (-40C) to 140F (+60C).

BD-5001

BLL510

Keypad/Display, 2 line X 16 characters, LIQUID CRYSTAL DISPLAY (LCD), with cable. Operates -4F (-20C) to +140F (+60C).

BD-5001

129-178-4

Kit, remote mounting, BurnerLogix display, 4 ft. cable, provides NEMA 4 protection

133-675

129-178-8

Kit, remote mounting, BurnerLogix display, 8 ft. cable, provides NEMA 4 protection

133-675

BLD500

Blank display module for BurnerLogix.

-

PROGRAMMER MODULE (FOR BOTH Y AND Z MODULES)

 

 

YP100

Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 second FFRT

YP-1001

YP102

Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 2 second FFRT

YP-1001

YP113

Keypad selectable parameters, open/closed damper proving, 10 sec low fire start time, non-recycle operation, fixed TFI times, pilot proving, modulation, 1 second FFRT. Required for CE applications.

YP-1001

YP115

Keypad selectable parameters, includes 0 sec purge time, fixed 0 sec low fire start time, non-recycle operation, fixed TFI times, pilot proving, modulation, open/closed damper proving, 1 second FFRT. Required for CE applications.

YP-1001

YP118

Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, indefinite pilot hold, revert to pilot from auto, 1 second FFRT

YP-1001

YP138

Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Powered inputs provide indefinite hold, pilot hold, revert to pilot from auto.

YP-1001

YP183

Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Unpowered inputs provide indefinite hold, pilot hold, revert to pilot from auto. Provides purge complete output.

YP-1001

YP200

Keypad selectable parameters, recycle operation, modulation, 4 second FFRT

YP-1001

YP202

Keypad selectable parameters, recycle operation, modulation, 2 second FFRT

YP-1001

YP300

Keypad selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT

YP-1001

YP302

Keypad selectable parameters, recycle operation, low fire start, early spark termination, 2 second FFRT

YP-1001

WIRING BASE - Y MODULE

 

 

60-2810-1

Pigtail wires, 4 foot long, 4"W x 5"H, color coded and labeled.

133-676

60-2812-1

Closed base with terminal block and knockouts, 4"W x 7"H. UL Listed.

133-677

60-2814-1

Open base with terminal block. 4"W x 7"H  UL Recognized.

133-677