70D40 / 70D41
Flame switch and manual burner control, Can be used with a variety of flame sensing devices. Fitted to ABB gas turbines.
Description
FIREYE® Series D40-41 Burner Management Controls provide ignition and flame failure protection for manually started oil or gas burners. Plug-in Amplifier Modules permit the selection of ultra- violet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If flame signal (real or simulated) is detected, the unit cannot be started. For increased safety and reliability, Fireye 72D1R3 AUTOCHECK infrared amplifier (using the pulsing flame signal) and 72DUVS ultraviolet amplifier (using a scanner shutter) check the function of the flame detecting system for component failure during each burner firing cycle. Meter test jacks on each amplifier module provide flame signal readout with a DC voltmeter. Flame failure response time is four seconds (max.). When amplifier modules with T suffix are used, the flame failure response time is reduced to one second (max.).
The control provides three SPDT and one SPNO load switches for external loads and starting circuits. Fireye D40-41 Burner Management controls may be adapted to a simple control system or as a building block with auxiliary devices to provide additional functions.
Available in Atex Enclosure
Use with the following flame scanners
UV1A Non Self Check UV Scanner
45UV5 Self Checking UV Flame scanner
48PT2 Auto Check IR flame scanner
PART NUMBER |
DESCRIPTION |
MANUAL NUMBER |
D SERIES CHASSIS |
|
|
70D10 |
Obsolete - Consult factory |
D-1020 |
70D20 |
Obsolete - Consult factory |
D-1020 |
70D30 |
Obsolete - consult factory. |
D-30 |
70D40 |
Chassis, For manually ignited burners, 120 VAC. |
D-4041 |
70D41 |
Chassis, For manually ignited burners, 230 VAC. |
D-4041 |
FLAME AMPS |
|
|
72D1R1 |
Infrared auto-check amplifier, 2-4 sec FFRT, use with 48PT2. |
D-1020 D-30 |
72D1R1T |
Infrared auto-check amplifier, 1 sec FFRT, use with 48PT2. |
D-1020 D-30 |
72D1R3 |
Infrared auto-check amplifier (for special application - consult factory), use with 48PT2. |
D-1020 D-30 |
72D1R3T |
Infrared auto-check amplifier (for special application - consult factory), 1 sec FFRT, use with 48PT2. |
D-1020 D-30 |
72DRT1 |
Flame rectification amplifier, 2-4 sec FFRT, use with 45CM or 69ND. |
D-1020 D-30 |
72DRT1T |
Flame rectification amplifier, 1 sec FFRT, use with 45CM or 69ND. |
D-1020 D-30 |
72DUV1 |
Ultraviolet amplifier, 2-4 sec FFRT, use with UV1, UV2, 45UV3. |
D-1020 D-30 |
72DUV1T |
Ultraviolet amplifier, 1 sec FFRT, use with UV1, UV2, 45UV3. |
D-1020 D-30 |
72DUVS1 |
Ultraviolet self-check amplifier, use with 45UV5-1006. |
D-1020 D-30 |
72DUVS1T |
Ultraviolet self-check amplifier, 1 sec FFRT, use with 45UV5-1007, -1008, -1009. |
D-1020 D-30 |
72DUVS4 |
Ultraviolet self-check amplifier, 2-4 sec FFRT, use with 45UV5-1007, -1008, -1009. |
D-1020 D-30 |
Features
This unit can be used as a flame switch only or as a Manual burner control as below:
Part Number |
Description |
Manual Number |
ACCESSORIES FOR CONTROLS AND AMPLIFIERS |
||
7-1040 |
300MFD capacitor to increase 25SU3-4169T FFRT. - OBSOLETE |
CX-784 |
23-90 |
Replacement fuse for 25SU3-4169T, -5172, -5173. 1.0 amp. |
- |
23-93 |
3.0A fuse for 60-2204-2 (25SU5), 60-2203-2 (25SU3), and 25SU3-2000 (power). See 23-182 |
- |
23-121 |
Fuse for 60-1706 rack. - OBSOLETE |
- |
23-173 |
Replacement fuse for 25SU3-5166, -5168. 1.0 amp. |
- |
23-182 |
1.5 A fuse for 25SU3-2100, 2150 (power and RF1), 25SU3-2000 (RF1) and 25SU3-2000 (power) for date codes between 9706 and 9824. |
- |
23-184 |
Replacement fuse for 19UVPS and 192SU3. |
- |
23-194 |
Replacement fuse for 19MPS, 400 mA. |
- |
48-1805 |
Mounting screw for E100, E200, E340, 25SU5-5011, -5166. |
- |
60-1519 |
Sensitivity selector plug with cable for 25SU5-4011. - OBSOLETE |
CU-13 |
60-2067 |
Front panel filler plates (2) for 60-1706 rack. - OBSOLETE |
CU-23 |
60-2203-2 |
25SU3-5166, -5168 chassis. |
CX-742 |
60-2203-3 |
25SU3-5167 chassis - OBSOLETE |
CX-742 |
60-2204-2 |
25SU5-5011, -5012 chassis. |
CU-27 |
60-2205 |
Display module for 25SU5-5011/50125166/5168. |
CU-27 / CX-742 |
60-2206-1 |
25SU5-5011, -5012, -5013 wiring base. |
- |
60-2206-2 |
25SU3-5166, -5168 wiring base. |
- |
60-2207-1 |
Flame amplifier (High sensitivity) for 5011, 5168. |
CU-27 / CX-742 |
60-2207-2 |
Flame amplifier (High discrimination) for 5012, 5166, 5167. |
CU-27 / CX-742 |
60-2207-3 |
Flame amplifier (High sensitivity, no hysteresis) for 5013. |
CU-27 / CX-742 |
60-2223 |
Dust cover. |
- |
60-2301 |
Blank display module. |
- |
60-2367 |
Ribbon cable for 25SU5-5011/5012/5166/5168. |
CU-27 / CX-742 |
60-2470-1 |
110 VAC input/24 VDC, 2.5 amps output power supply. Includes 60-2482 connector. |
133-566 |
60-2470-2 |
220-240 VAC input/24 VDC, 2.5 amps output power supply. Includes 60-2482 connector. |
133-566 |
60-2471-1 |
Half rack for 25SU3-2000, -2100. Includes one 60-2478 connector. |
CU-34 |
60-2471-3 |
Full rack for 25SU3-2000, -2100. Includes one 60-2478 connector. |
CU-34 |
60-2478 |
Screw terminal, straight style (12 AWG) connector for 25SU3-2000, -2100 and 19UVPS. |
CU-34 |
60-2480 |
Screw terminal, Y style (12 AWG) connector for 25SU3-2000, -2100 and 19UVPS. |
CU-34 |
60-2481 |
Screw terminal connector for 60-2470, 19MPS. |
CU-34 |
60-2482 |
Spade terminal connector for 60-2470, 19MPS. |
CU-34 |
60-2490-2 |
Front filler plate for 60-2471-1, -3. Approx .4" (2 HP). |
- |
60-2490-4 |
Front filler plate for 60-2471-1, -3. Approx .8" (4 HP). |
- |
60-2490-6 |
Front filler plate for 60-2471-1, -3. Approx 1.2" (6 HP). |
- |
60-2490-8 |
Front filler plate for 60-2471-1, -3. Approx 1.6" (8 HP). |
- |
60-2490-10 |
Front filler plate for 60-2471-1, -3. Approx 2" (10 HP). |
- |
60-2530-1 |
Surface mount rack for use with 25SU3-2000, -2100 amplifier and 19MPS-2000 power supply. |
CU-44 |
60-2530-2 |
Surface mount rack with hinged clear plastic cover for use with 25SU3-2000, -2100 amplifier and 19MPS-2000 power supply. |
CU-44 |
19MPS-2000 |
Multi-purpose power supply for 25SU3-2000, -2100 and associated high and low voltage scanners. |
CU-45 |
19UVPS-2120 |
120 VAC, 19" power supply for 45UV5, 45RM1, and 45RM2 scanners. |
CU-38 |
19UVPS-2220 |
220 VAC, 19" power supply for 45UV5, 45RM1, and 45RM2 scanners. |
CU-38 |
192SU3-2120 |
19" adapter (120 VAC) to retrofit 25SU3-2000, -2100 to 60-1706 rack. |
CU-36 |
192SU3-2220 |
19" adapter (220 VAC) to retrofit 25SU3-2000, -2100 to 60-1706 rack. |
CU-36 |
SIGNAL METERS |
|
|
38-54 |
Flame meter, 2 1/4 inch square, 0-3 VDC, 20K ohm/volt. |
- |
38-55 |
Flame meter, horizontal, 0-3 VDC, 20K ohm/volt. |
- |
38-56 |
Flame meter, vertical, 0-3 VDC, 20K ohm/volt. |
- |
38-62 |
Flame meter, horizontal, 0-3 VDC, 20K ohm/volt. - OBSOLETE |
- |
38-88 |
Analog bar graph meter (LED), 0-3 VDC. |
CU-24 |
38-96 |
Flame meter, 2 1/4 inch square, 4-20 mA. |
- |
38-97 |
Flame meter, horizontal, 4-20 mA. |
- |